KGPS Series Resonant Dual Track and One-Tow-More
1965-07-17
  • KGPS Series Resonant Dual Track and One-Tow-More
  • KGPS Series Resonant Dual Track and One-Tow-More
Product Featufes
Product Advantages
Basic Parameters

1. Thyristors, chucking appliances and water-cooled radiators of well-known brands; all-purpose main switch with current display; copper coil of large size; 6-pulse and 12-pulse, ensuring equipment stability.


2. Design of series resonance; the rectification part of the power supply cabinet adopts a fully open design. Therefore the power factor is the highest while the higher harmonic is the lowest. It is not necessary to equip reactive power compensation and harmonic elimination devices, reducing equipment investment.


3. Digital electronic control; all trigger signals are transmitted through optical fiber, with strong capability of anti-interference; the rectification trigger board allows the current to be automatically balanced, realizing the soft start and preventing the impact on the power supply; working as fast electronic switch that cuts off the power in the event of a malfunction.


4. The layout of the power supply cabinet components is reasonable; the maintenance personnel can easily access all the maintenance points; the open structure design of electric furnace makes maintenance easy.


5. Competitive power consumption indicator; for medium frequency smelting furnace, the power consumption per ton is ≤ 510 degrees/ton; in addition, the power supply cabinet is equipped with a smelting manager. PLC and human-machine interface constitute a smelting manager easy for operation, with functions of automatic furnace drying, furnace start under cold state, malfunction diagnosis, fault information display and storage, operation information display, system status display, etc.


6. Good environmental protection performance: compared with the parallel power supply, the noise of the overall unit is stable and light, which is ≤85dB measured at the position where the operating platform is two meters away from the furnace, with no noise wave; the pollution of the medium frequency harmonics to the power grid is small.

 ModelInlet Voltage (V)Inlet Current (A)DC Voltage (V)DC Current (A)MF Voltage (V) MF Frequency (HZ)MF Power (Kw)
KGPS-DX-250KW   575V/3N262  775v322A  2600V  500HZ-1000HZ250KW
KGPS-DX-500KW525A644A500KW
KGPS-DX-800KW840A1030A800KW
KGPS-DX-1000KW   575V/6N525A   775V644A   2600V   300HZ-500HZ1000KW
KGPS-DX-1500KW788A966A1500KW
KGPS-DX-2000KW1052A1290A2000KW
KGPS-DX-2500KW1315A1610A2500KW
KGPS-DX-3000KW   575V/6N1580A   775V1930A   2600V   200HZ-300HZ3000KW
KGPS-DX-3500KW1840A2255A3500KW
KGPS-DX-4000KW2100A2578A4000KW
KGPS-DX-4500KW2630A2900A4500KW
KGPS-DX-5000KW   575V/6N2630A   775V3220A   2600V   200HZ-250HZ5000KW
KGPS-DX-6000KW3155A3155A6000KW
KGPS-DX-8000KW4206A4206A8000KW
KGPS-DX-10000KW  575V/6N5260A 775V5260A 2600V 100HZ-200HZ10000KW
KGPS-DX-15000KW7890A7890A15000KW


Last item:This is the first one